Compressors command unit EFT02

The EFT02 is a graphic command unit, which realizes, together with the regulation form RES02, a complete command and regulation system for compressors. Different models of ammonia or freone compressors can be connected. The command unit contains a graphic display allowing a clear visualisation of the system and guarantees an intuitive and safe usage. The main menu shows in a schematic form the most important refrigeration part of the system and also informs about the working state besides showing the measured values. 
There are also various under-menu containing more detailed information about the compressors status and about the system, in general. All the measured value can be shown as text while for some other graphics are available, too.
Furthermore there is also a log form which can be reviewed and contains all the executed actions of the system. The form include a precise information about the execution time. This aspect can be very useful when you are looking for a possible damage or error. A counter informs about this situation noticing if or when there is something to do about maintenance.

Structure

The EFT02, together with the regulation form RES02, a complete command and regulation system for compressors. The two equipments are connected and communicate by a serial interface. The RES02 form deals with regulation and management of the digital inputs and outputs and with the recording of the measured analogical values. The data are exchanged between the two units and the EFT02 shows all these information presenting itself as instrument/user interface.
The system is completely enlargeable. Other EFT02 command units and RES02 regulation units can be added. This aspect can be necessary when many compressors are used.

Function

Soon after the refrigeration system turning on, the EFT02 realizes a security test on the compressors and the hydraulic installation. That is necessary to be certain that it is possible a safe start of the compressor. In case, for instance, of not good working of the oil pump or dirty oil filter, an advice is shown on the display and the system start is stopped. A note on the log form is shown, too. If in the system there is more than one compressor, the regulation system surveys the working state and, depending on the cold request, turns on or off one or more compressors. The compressors turn on follows a precise fix order and a compressor turns on only when the previous one is working at its maximum power. 
During their working different precision sensors give an exact description of the current status and let the regulation unit keep the desired values.